Automatic algorithms for stent struts segmentation in optical coherence tomography (OCT) images of coronary arteries have been developed over the years, particularly with application on metallic stents. The aim of this study is three-fold:
- to develop and to validate a segmentation algorithm for the detection of both lumen contours and polymeric bioresorbable scaffold struts from 8-bit OCT images,
- to develop a method for automatic OCT pullback quality assessment, and
- to demonstrate the applicability of the segmentation algorithm for the creation of patient-specific stented coronary artery for local hemodynamics analysis.
Methods
The proposed OCT segmentation algorithm comprises four steps:
- image pre-processing;
- lumen segmentation;
- stent struts segmentation;
- strut-based lumen correction.
This segmentation process is then followed by an automatic OCT pullback image quality assessment. This method classifies the OCT pullback image quality as ‘good’ or ‘poor’ based on the number of regions detected by the stent segmentation. The segmentation algorithm was validated against manual segmentation of 1150 images obtained from 23 in vivo OCT pullbacks.
This is one of the scientific articles published by one or more synbrAIn collaborators and data scientists.